About 74,800 results
Open links in new tab
  1. CRAH Unit, Computer Room Air Handler | Trane Commercial HVAC

    A Computer Room Air Handler (CRAH) is a cooling unit used to regulate the temperature and ensure optimal operating conditions for IT equipment. CRAH units are essential for cooling central IT …

  2. What is CRAC? CRAC vs. CRAH Unit Differences - TechTarget

    Jun 10, 2025 · Computer room air handler (CRAH) units are another data center cooling device. The main difference between CRAH and CRAC units is how they cool their surrounding environments.

  3. What Is The Difference Between CRAC & CRAH Units? DataSpan

    Dec 10, 2021 · The main difference between CRAC and CRAH cooling units is that CRAC units use refrigerants and compressors, whereas CRAH units use chilled water and control valves.

  4. CyberAir Computer Room Air Handlers and Air Conditioners from …

    With 20 kW - 1,080 kW of cooling capacity, there is an air conditioner (CRAC) or air handler (CRAH) for almost any mission critical application. Find your local Sales Representative

  5. MC CRAH Unit | YORK®

    All units are constructed and designed with gallery side maintenance for quick service access, including fans, filters, electrical, coil drain and coil vent. These CRAH’s have a compact design in the direction …

  6. CRAC Unit Vs CRAH Unit | What's The Difference ...

    Aug 13, 2023 · A CRAC Unit transfers the heat from the system and ejects by only using the Refrigerant Cycle, whereas a CRAH Unit utilizes Chilled Water, the Refrigerant Cycle, and Condenser Water.

  7. CRAC / CRAHUs – Silent-Aire

    The CRAC / CRAH units are downflow as a standard, however, upflow and horizontal configurations are available. As a custom manufacturer we can accommodate other configurations and sizes.

  8. Dive Into Data Center Cooling: CRAH vs CRAC

    The acronyms CRAH (pronounced “kraw”) and CRAC (pronounced “krak”) stand for Computer Room Air Handler and Computer Room Air Conditioner respectively. As is common knowledge, most facilities …

  9. CRAH Units - Koch Applied

    Computer room air handlers (CRAH) units are specialized cooling systems designed for data centers and other mission-critical environments where maintaining optimal temperatures is essential for …

  10. CRAC and CRAH Cooling Unit HVAC Differences Explained

    Jan 20, 2023 · A CRAH HVAC system blows air over cooling coils, similar to a CRAC system. But the main difference is these cooling coils are filled with chilled water instead of refrigerant.